Monday, May 20, 2013

Energy Savings

HERS Rating: 57% Improvement over Code  (What is a HERS rating?)


Projection: 80% Improvement over Code
  • load calculations from HVAC engineer of the highly efficient geo-thermal system together with infrequent usage of the system due to the Owner's preference for the designed natural ventilation
  • ceiling fans
  • CFL Energy Star and low-wattage LED fixture
  • all Energy Star appliances
  • ERV (what is an ERV?)
  • Rainwater collection pumps
  • Photovoltaic production contributing to Net Usage




Actual: 85% Improvement 
  • One year of energy bills logged and added up



Rainshine's actual energy consumption for 2010, the first full year of occupied operation, is remarkable.
The 2008 HERS (Home Energy Rating System) rating projected only a 57% improvement over code for RainShine.  Not pleased with the HERS rating we chose to conduct our own calculations and projected usage averaging $71.22 per month, an 80% improvement over a code compliant house.

We were confident in our numbers and knew HERS did not consider a variety of factors contributing to energy consumption. Among them:
1. The microclimate of the house
2. The extensive passive solar feature such the overhanging eaves, light shelves and east/west windows located to reduce solar gain through screening from existing trees.
3. The critical factor of the willingness of the clients to live a sustainable life in a sustainable house.

To prove our calculations we tracked the house's actual occupied energy consumption and photovoltaic production for 2010. Average gross utility cost per month was $48.57, an 85% improvement over code. A few more photovoltaic panels and the house would be net zero. 

The most disappointing result from our survey was photovoltaic production. Our calculations were based on a site specific calculation provided by the manufacturer who estimated (conservatively according to them) generation of 7,500 kWh/yr. Only 3,155 kWh were generated in 2010, less than half of the projection and a shortfall of $740 for the year and an average of $60 per month. If the PVs had performed up to snuff the house would easily be net zero. 

Conclusion: energy projections can be, as we all know, misleading and every house should be tracked to determine actual energy consumption. In general we were delighted with Rainshine's real-life performance. Rainshine proves how energy efficient thoughtfully combining site features, orientation, passive solar design concepts with active systems can be (even when incorporating major areas of glass). Kudos to the owner and design team!

Throwing features and systems at house designs in order to improve energy performance is, as I suspect HERS is necessarily dumbed down to do, wasteful and counterproductive. As in Rainshine an energy efficient house should look like an energy efficient house, not a neo-eclectic mishmash with energy features screwed in/tacked on a sideways compromising manner.

Thursday, November 19, 2009

Passive Solar Techniques in Diagram







Monday, December 8, 2008

Energy Consumption for LEED

Active techniques to reduce consumption of energy include:

1. Two two-stage zoned ground-source heat pumps provide heating and cooling. The heat pumps provide air distribution that will adjust to the variation in loads throughout the areas of the house throughout the day and will provide both temperature and dehumidification control.

2. A desuperheater is coupled to each of the two geothermal heat pumps and heats water with energy that would otherwise be given up to the heat sink of the closed loop wells. When the heat pumps are operating, hot water is virtually free. Hot water is stored in high efficiency hot water heaters that serve as backup hot water generators when the geothermal heat pump system is not in operation.

2. An energy recovery ventilator provides balanced introduction of fresh filter/conditioned air and reclamation of invested energy from air typically exhausted from bathrooms, kitchen and laundry.

3. Lower capacity high efficiency two-stage zoned geothermal heat pumps will provide the necessary heating and cooling with controlled airflow to the zones that require conditioned air which can be as low as a few hundred cfm per zone. For most of the year 1200 cfm provides required conditioning, 2000 cfm on the very hottest or coldest days compared to 3,600 cfm required in code compliant designs.

4. A net-metered roof mounted 3.1 kilowatt photovoltaic system. The system, consisting of 18 high-efficiency monocrystalline photovoltaic modules, is mounted on the south-facing portion of the butterfly roof. Through the Georgia Power Net Metering System, all power generated from the photovoltaic system is independently metered and made available to Georgia Power for it’s Green Energy program. Georgia Power pays 17.4 cents per kilowatt hour for power generated by the system. Energy consumed by the house is obtained from the grid at 8.64 cents per kilowatt hour and is monitored by a separate meter. As incentive, this system has received a $10,500 state tax credit and is eligible for a $2,000 federal tax credit.
The system was installed and activated shortly after completion of framing and roofing. It generated and sold power during the remainder of the construction period.

5. Energy Star appliances.

6. All light fixtures employ LEDs or are fluorescent Energy Star rated and, in total, consume 1/10 of the power of a similar code compliant house using conventional fixtures.

Friday, August 29, 2008

Yearly Cost Projections

Below is a spreadsheet using information calculated by RMCA, the engineers and the manufacturers projecting the yearly net and gross kWhs and billed costs. The rate is per the EIA rate chart.


Monday, August 18, 2008

Appliances' Energy Consumption

Below is a spreadsheet showing projected annual energy consumption by appliances alone.










Sunday, August 10, 2008

Appliances

The major appliances in the house are Energy Star compliant. The selections are as follows:

  • Cook top: Electrolux Induction Cooktop E301C75FSS
  • Oven: Electrolux Single Oven EW30EW55GS
  • Microwave: Electrolux EI30MO45G
  • Dishwasher: ASKO D3251XLFI
  • Refrigerator: Frigidaire GHSC39ETJS
  • Washer: Frigidaire F/L ATF8000FS
  • Dryer: Frigidaire F/L AEQ8000ES